|
|
|||||
|---|---|---|---|---|---|
|
|
In order to assist developers, engineering consultants, contractors, and planners as they prepare projects for evaluation by the RWU engineering staff, we are now providing details, guidelines, and specifications for download. As revisions, additions, and changes are made, the documents are updated on this website, and the revision and effective date are given for each document.
Your Rogers Water Utilities Engineering contact will inform you of the documents that apply to your project, please download them and familiarize yourself with their contents. Many common questions are answered in these documents. As always, if you have further questions, your Rogers Water Utilities Engineering department will be pleased to help.
|
||||
|
Current Notices: |
|||||
|
Effective June 9, 2006, developers will have the option of
setting 1-1/2 and 2 meters and construction of the related meter
boxes. RWU will continue to do these installations, if requested, but
do offer the Developer the opportunity to do this work providing better
control of their construction schedule.
_____________________________________________
The following sections are hereby revised in the Standard
Specifications For Construction of Public Water and Sewer Improvements
in the City of Rogers and Areas Under the Jurisdiction of Rogers
Waterworks and Sewer Commission, dated August 1996, revised April 16,
1997. The summary of revisions is as follows: The Summary of Revision No. 9 encompasses the revision of Sections 02-07, 02-11 and 07-04 to the Water and Sanitary Sewer Standard Details; the addition of Sections 02-16, 04-10, 07-05 and 07-06 to the Standard Specifications; effective 8/16/2007. Summary of Revision No. 8 encompasses the revision of Sections 02-01, 02-13 and the Water and Sanitary Sewer Standard Details; the addition of Sections 06-02, 07-01, 07-03 and 07-04 to the Standard Specifications; effective 12/12/2006. The Summary of Revision No. 7 encompasses the revision of Sections 02-06, 02-11, 02-13 and 04-07 and the addition of Sections 04-09, 05-03, 06-04 and 07-02 to the Standard Specifications; effective 08/22/2006.
The Summary of Revision No. 6 encompasses the revision of Sections 02-10 and 03-04 and the addition of 02-13, 04-04, 04-05, 04-06, 04-07 and 04-08 to the Materials Standard Specifications; effective 06/12/2006.
All other sections of the said standard specifications remain in effect.
_____________________________________________
GUIDELINE ADDITIONS - 02/06/2006
Commercial Cross Connection Control and Fire Prevention System Guideline Checklist ____________________________________________________________
CHECKLIST ADDITIONS - 02/06/2006
RWU WATER SYSTEM INSPECTION ACCEPTANCE CHECKLIST RWU SEWER SYSTEM INSPECTION ACCEPTANCE CHECKLIST
|
|||||
|
DOCUMENTS
Resolutions and Legal Notices
Resolution 05-05 and Resolution 03-07 Regarding Water / Sewer access and hookup fees - PDF Resolution 05-05 Approved November 2004, Resolution 03-07 Approved September 2006, Access Fees effective April 01, 2005, Hookup Fees effective April 01, 2006
Resolution 06-202 Regarding New Sewer rate schedule - PDF Resolution 06-202 Approved December 2006, first
Sewer Rates increase effective February 01, 2007, second increase
effective February 1, 2008
Forms, Agreements, and Other Documents
Easement Document - Word Document Posted February 16, 2006
Cost Certification Forms - PDF Document Posted May 02, 2006 RWU Bond Requirements - PDF Document Posted April 04, 2007
Rogers Water Utilities Details (Standard Details. Right-click on link and click 'save link as' or 'save target as' to download and view drawings)
Rogers Water Utilities Standard Water Details 1 Revised August 2007 ACAD .DWG file Click HERE ADOBE .PDF file Click HERE
Rogers Water Utilities Standard Water Details 2 Revised January 2008 ACAD .DWG file Click HERE ADOBE .PDF file Click HERE
Rogers Water Utilities Standard Sewer Details 1 Revised August 2007 ACAD .DWG file Click HERE ADOBE .PDF file Click HERE
Rogers Water Utilities Engineering Guidelines (Guidelines - PDF files)
Rogers Water Utilities Plan Preparation Guideline Checklist New Document - Effective December 12, 2005
Commercial Cross Connection Control & Fire Prevention System Guideline Checklist New Document - Effective February 1, 2006
Rogers Water Utilities Service Meter Sizing Information New Document - Effective Feb 21, 2007
Rogers Pollution Control Grease and Sand/Oil/Water Interceptor Questionnaire New Document - Effective May 8, 2006
Rogers Pollution Control Grease Interceptor Sizing Worksheet New Document - Effective May 8, 2006
Rogers Water Utilities Inspection Checklists (Guidelines - PDF files)
RWU Water System Inspection Acceptance Checklist New Document - Effective February 1, 2006
RWU Sewer System Inspection Acceptance Checklist New Document - Effective February 1, 2006
Rogers Water Utilities Standard Specifications (Specifications - PDF files) |
|||||
|
|
|||||
|
|
|||||
|
Rogers Water Pollution Control Facility Documents Grease Interceptor
Configuration Drawing Elevator Sump w/Barrel Containment Drawing New Document, effective December 2006 ACAD .DWG file Click HERE ADOBE .PDF file Click HERE .DXF file Click HERE .DWF file Click HERE
Links
Arkansas Department of Health and Human Services Water Bacteriological Testing Results
|
|||||
|
|
|||||
|
HOME About RWU
At A Glance Rates Direct
Bank Draft Mission Statement 601
S 2nd Street · Rogers AR 72756 |
|||||